Insights · Verification · 4 min read

Why an optimized part has to be analysed again

An optimizer reports how stiff its result is. That number describes the optimizer's model, not the part that will be built. One worked example shows how far apart the two can be.

A topology optimization ends with a shape and a number: the stiffness the optimizer reached. It is tempting to put that number into the report. This article follows one study, a bearing housing, through the step that comes afterwards, and shows what that step found. The complete study is our sample report.

The clip shows the solid housing, the optimizer removing almost two thirds of it, the result rebuilt as a CAD solid, and finally the stress on that solid.

Three different objects

On the way from the optimizer to the drawing, the part exists as three different objects. The first is a field of densities on a grid: cells that are full, empty, or something in between. The second is the surface drawn where the density crosses one half, made of thousands of facets. The third is the CAD solid rebuilt from those facets, with smooth surfaces that follow them closely but not exactly. Only the third can be manufactured, and the optimizer analysed only the first.

What the second look found

We analysed the rebuilt solid again under the same load, in two ways that share no mesh — once in a regular grid that the solid cuts through, once on a mesh fitted to its CAD faces — and refined both. The optimizer had reported a stiffness of 496 kN/mm. The rebuilt solid on the same coarse grid gave 503. On finer grids the value fell: 474, 470, 463. A mesh fitted to the CAD faces gave 456, 456 and 454, almost regardless of its size. The two methods end 1.9% apart.

So the optimizer's number was 9% too high, and not because the reconstruction had changed the part. The cause was the grid. A grid fine enough to find where the material should go is not fine enough to say how stiff the result is. An optimizer runs a hundred analyses, so its grid is chosen for speed. That is reasonable, as long as nobody quotes its numbers.

A number that would not settle

The peak stress behaved differently. It rose with every refinement, from 195 to 495 MPa, and showed no sign of stopping. It sits in a sharp inner corner, where in theory the stress has no upper limit. That is a property of the model, not of the part: a real housing has a fillet there. The honest statement is that this study gives no peak stress, and says what it would take to get one.

The last step

None of this is exotic. It is what a second analysis, of the geometry that is actually handed over, routinely turns up: one number that was too optimistic, and another that was never a number. Design, simulate, optimize, rebuild, verify. The last step is where a result becomes something you can put your name to.

← All articles

Wondering whether this
fits your problem?

Send us a geometry and a short description, and we will take a first look.